Sorry, Only members of Healium network are allowed to transact on the platform. Click here to apply for membership.
Anesthesia Apparatus – URJA MINT
Anesthesia Apparatus- URJA MINT has 5 Tube Rotameter, Hypoxia, ORC for Low Flow Anesthesia with cylinders attachment for O2 &N2O. DISS Fitting for O2, N2O & Air.
Sorry, this product is not refundable.
Anesthesia Apparatus – URJA MINT
Anesthesia Apparatus – URJA MINT – Reuben’s Anesthesia Apparatus
With Std. Accessories [ Model:- Urja Mint]
With Autoclavable Circle Absorber
With Ventilator & Vaporiser
RATE: Rs. 50,000/-
Anesthesia Apparatus – URJA MINT
Important Highlights:
Specification Of Anesthesia Apparatus- URJA MINT
- UrjaMint Anesthesia Workstation with the following parameter
- 5 Tube Rotameter, Hypoxia, ORC for Low Flow Anesthesia with cylinders attachment for O2 &
N2O & central supply inlet for oxygen O2, N2O & Air. - DISS Fitting for O2, N2O & Air.
- System on/off switch & Ventilator driving gas Selecta switch
- Hospitech provides proximal sensors wherein the measurement of set tidal volume & delivered
tidal volume is displayed on the screen & also help determine the exact delivered and set
parameters after the Patient. - Ancillary flowmeters for oxygen is provided by standard accessories
- Attachment for compressed medical air for driving the ventilator and Air oxygen mixture from
rotameter for the patient is possible, hence reduces the use of N2O oxide theatre pollution &
reduces the consumption of O2 by 80 %. - Two drawers working tabletop and Top shelf.
Anesthesia Ventilator : - Features :
- 6.1” Tft Color Display
- Application:, Pediatric And Adults
- Tidal Volume Setting 50 -1500ml
- Ventilation Modes: VCV,PCV, Manual / Spontaneous mode
- Friendly User Interface, Display Paw-T, Flow-T Curve
- Built-In Active Expiratory Peep Valve: Built-In Battery for 2 hours
- Easily Removable And Serializable Flow Sensor Module
Measurement : - Pressure Values: Ppeak, Plat, Pmean, Pmin, Peep
- Volume/Flow Values: Vt1, Vte, Mv,Mvspont
- Ftotal, Fspn, I:E, Rinsp, Cdyn
- Pressure- Volume, Volume-Flow waveforms
Alarms : - Mv, Paw, Vte, Rate, Fio2, Mains Failure, Battery Low, Battery Discharged,
- O2 Supply Failure, Apnea, Circuit Occlusion.
Battery: * 2 hours
Autoclavable Circle System :
RATE: Rs. 50,000/-
- With Circle On/Off switch
- Bi –Stable Bag / Ventilator selector switch.
- Designed for Low flow with 1 ltr capacity
- Single lever mechanism for changing soda lime during operation without disconnecting patient.
- Entire unit with patient bellows system Autoclavable @ 134 deg. Centigrade
Tec Vaporizer :
RATE: Rs. 65,000/-
- Approximately Weight 5 Kg.
- Volume At Max Mark: 250ml. Nominal Volume At
Min Mark: 35+10ml.
After Draining, Approximately
60+10ml Of Liquid Is Retained By The Wick. - Operating Flow Range: 0.2 To 15 Litres/Min.
- Operating Temperature Range: 15 To 35oc (58 To 95of)
- 0.2% To 5 %
- Presumes Ten Year Product Life Requiring No Preventive Maintenance Service. It Is Recommended That A Service Is Carried Out At Ten Years. Halothane Vaporizers Require A Five-Year Service.
Spread the love
- 16Shares
Only logged in customers who have purchased this product may leave a review.
Need Help? Contact Us Leave Feedback
Category: B2B Facilities
Tags: anesthesia, Anesthesia Apparatus, Anesthesia Apparatus- URJA MINT, hospitech, urja mint
Contact Us
Enter your contact details or email form shortcode here. (Text/HTML/Shortcodes accepted).
Leave Feedback
Enter your feedback modal content here. (Text/HTML/Shortcodes accepted).
Reviews
There are no reviews yet.